MedART is Compliance-Ready — Architecture designed to support HIPAA, GDPR & regional regulatory requirements.
Andrology Module WHO 6th Edition 2021 CASA Integration

Andrology Software Built to
the Latest WHO Standard

WHO 6th Edition 2021 reference ranges, CASA system import, DFI tracking, and surgical retrieval documentation — purpose-built for IVF andrology labs.

Built for andrology labs that report to WHO standards, not to a free-text note field.

View MedART
WHO 6th Edition 2021
CASA Integration
DFI Tracking
Andrology Report
Semen Analysis — WHO 6th Edition (2021)
Parameter
Result
Reference
Status
Concentration 42 ×10⁶/mL ≥16 Normal
Total Motility 54% ≥42% Normal
Progressive Mot. 48% ≥30% Normal
Morphology (Kruger) 3% ≥4% Below Ref
Volume 3.2 mL ≥1.4 mL Normal
DNA Fragmentation 18% <25% Borderline
Report auto-generated · WHO 6th 2021
Dr. Ahmed signed

Built to the Latest WHO Standard

MedART Andrology ships with WHO 6th Edition (2021) reference ranges pre-loaded. Every parameter field is mapped to the new lower reference limits, and the report auto-flags values outside range at the point of entry — no manual threshold lookup required.

  • WHO 6th Edition 2021 reference limits pre-configured — updated from 5th edition
  • Concentration, motility (total and progressive), and morphology (Kruger strict criteria)
  • Volume, pH, viscosity, liquefaction time, and round cell count
  • DNA Fragmentation Index (DFI) — TUNEL, SCSA, SCD method support
  • Auto-flagging of abnormal values with colour-coded status indicators
  • Signed report PDF generated automatically for patient file and referral

Direct Import from Your CASA System

Computer-Assisted Sperm Analysis data flows directly into MedART from your CASA hardware — no manual transcription, no data entry errors. Kinetic parameters captured automatically and stored against the patient and cycle record.

  • Microptic SCA, Hamilton Thorne IVOS / CEROS, Hobson SpermTracker
  • Generic HL7 lab interfaces for other CASA systems
  • Kinetic parameters: VCL, VSL, VAP, LIN, STR, WOB, ALH captured in full
  • Motile concentration, progressive motile count, and rapid progressive fraction
  • No manual transcription &mdash; zero data entry errors between CASA and MedART
CASA Import
CASA Data Import — Microptic SCA
Connected · Last sync 10:23 AM
VCL (velocity) 48.3 µm/s
VSL (straight-line) 31.2 µm/s
VAP (average path) 38.7 µm/s
LIN (linearity) 0.65
STR (straightness) 0.81
Motile concentration 22.6 ×10⁶/mL
Imported automatically — no re-entry required
Procedure Record
Surgical Retrieval Record
Procedure TESA
Anaesthesia Local
Yield Motile sperm confirmed
Immediate use Yes — ICSI same day
Cryopreserved 2 straws · Tank A · Goblet 3
Dr. Ahmed — Signed 11:05
14 Mar 2026 · Linked to Cycle 2026-03

Surgical Retrieval to Cryobank

TESA, PESA, TESE, and micro-TESE procedures are documented in structured forms that link directly to the patient cycle record. Yield, immediate use decision, and cryopreservation storage location are all captured in one workflow.

Procedure Documentation

  • TESA / PESA / TESE / micro-TESE structured records
  • Anaesthesia type, yield classification, and immediate use decision
  • Complication logging with structured code options
  • Physician e-signature at point of procedure

Sperm Cryopreservation

  • Vitrification and slow-freeze protocol fields
  • Tank, canister, and goblet location assignment
  • Straw count, cryoprotectant, and pre-freeze motility recorded
  • Thaw records linked to cycle and embryology module

See the Andrology Module in Action

Walk through WHO 6th Edition semen analysis, CASA import, and surgical retrieval documentation in a personalised MedART demo.

All Modules

Common Questions

Does MedART Andrology follow WHO 6th Edition 2021 semen analysis reference values?

Yes. MedART Andrology is updated for WHO 6th Edition (2021) reference limits — sperm concentration ≥16M/mL, total motility ≥42%, progressive motility ≥30%, morphology ≥4% normal forms (Kruger strict). Each parameter is displayed with the current reference range and flagged automatically when below threshold.

Can MedART import data from CASA systems?

MedART integrates with Computer-Assisted Sperm Analysis (CASA) systems including Microptic SCA, IVOS II (Hamilton Thorne), and SQA-Vision. VCL (curvilinear velocity), VSL (straight-line velocity), VAP (average path velocity), linearity, and other kinematic parameters are imported directly and stored against the semen analysis record.

What is DNA Fragmentation Index (DFI) and does MedART track it?

DNA Fragmentation Index (DFI) measures the percentage of sperm with damaged DNA. Clinically, DFI > 25–30% is associated with reduced fertilisation, poor embryo quality, and recurrent pregnancy loss. MedART records DFI from TUNEL, SCSA, or Halo assays alongside standard semen parameters, flagging elevated DFI for clinical review and TESA/PESA recommendations.

How does MedART handle surgical sperm retrieval documentation?

MedART documents TESA, PESA, MESA, and microTESE procedures with procedure type, anaesthesia, yield (motile sperm count), and immediate cryopreservation details. Cryopreserved surgical sperm samples are linked to MedCryo for tank location tracking, thaw scheduling, and renewal alerts.

For andrology leads

Request the WHO 6th-edition Andrology brief

A short brief on how MedART Andrology aligns to WHO 6th-edition semen-analysis criteria, CASA integrations, and cryopreservation traceability — for lab directors evaluating a switch.

Talk to Sales